Datasheet W181A-P091

Valve and motor drivers (PWM)

Issued 23 November 2026

4-20 mA to Danfoss PVE/PVG, ratiometric valve control with OLED display

Article number W181A-P091

W181 module in compact DIN rail enclosure, front three-quarter view: OLED display, three push buttons, DIP switch, USB-C port and screw terminals

A PVE 4-20 mA converter for anyone who wants to control a PVG 32 or other PVG valve with 4-20 mA, for example from a PLC or over a current loop on a long cable. The W181A-P091 generates the control voltage for the Danfoss PVE as a fraction of the PVE supply voltage: 25 % is full one way, 50 % neutral and 75 % full the other way. The reference is taken directly from the PVE supply, so the ratio is correct at any supply voltage. If the control drops out, at start-up or when the software stops, the output goes to neutral in hardware within approx. 0.1 s. Request price and lead time with the form on this page.

Price on request. Supplied in series, from 10 units per item. Not in stock? Then we build your series. One or a few units only as a trial, for a company with a series in sight.

Specifications

Supply24 V DC (±15 %)
Input4-20 mA
OutputRatiometric control voltage for Danfoss PVE: 25 / 50 / 75 % of the PVE supply (full / neutral / full)
IsolationNot galvanically isolated; module and PVE on the same 24 V
SetupOLED display with UP, DOWN and OK buttons; DIP switch for basic choices
Fail-safeOutput to neutral (50 %) in hardware at start-up or when the software stops
ProtectionReverse polarity protection and overvoltage protection (TVS)
USBUSB-C for software updates and reading the status
Wi-FiBuilt-in hotspot for software updates
MountingDIN rail, compact enclosure

Setup

  1. Connect the supply, the 4-20 mA source and the PVE according to the wiring diagram supplied with the module.
  2. Check the neutral position (50 %) and both end positions on the display.
  3. Set the limits at 4 and 20 mA if needed and save the settings.