Datasheet W181A-P505

I/O modules and communication

Issued 19 November 2026

Smart meter (P1 port) read out via Wi-Fi, with OLED display

Article number W181A-P505

W181 module in compact DIN rail enclosure, front three-quarter view: OLED display, three push buttons, DIP switch, USB-C port and screw terminals

The W181A-P505 is connected with an RJ12 cable to the P1 port of a smart meter (DSMR 2.2 up to and including 5). The module reads every telegram, shows the current values on the OLED display and sends them via Wi-Fi using MQTT to a server of your choice. The module takes its power from its own 24 V connection and therefore does not load the meter; this also makes it work on meters without power on the P1 port.

Price on request. Supplied in series, from 10 units per item. Not in stock? Then we build your series. One or a few units only as a trial, for a company with a series in sight.

Specifications

Supply24 V DC (±15 %)
InputSmart meter P1 port (DSMR 2.2 to 5), RJ12 or screw terminals
OutputWi-Fi with MQTT to a server of your choice
IsolationIsolation is in the meter (optocoupler)
SetupOLED display with UP, DOWN and OK buttons; DIP switch for basic choices
P1 portData Request switched, high-impedance at start-up; meter power not used; ESD protection on data and request
USBUSB-C for software updates and reading the status
Wi-FiBuilt-in hotspot for software updates
MountingDIN rail, compact enclosure

Connections

Terminal 3P1 data
Terminal 4P1 data GND
Terminal 5P1 data request

Setup

  1. Connect the supply and link the meter's P1 port with a straight RJ12 cable or via the terminals.
  2. Switch on the Wi-Fi hotspot on the display and enter your Wi-Fi network and the MQTT server details.
  3. Check on the display that telegrams are arriving.