Article number PR100s08
The PR100s08 converts the signal of a potentiometer from 500 Ω to 100 kΩ into a 0-5 V DC voltage. The output is calibrated with the push buttons: potentiometer in the position for 5 V, press the button; potentiometer in the position for 0 V, press the button. Fine adjustment by hand remains possible afterwards. The output is not galvanically isolated: the output minus is internally connected to the supply minus.
Price on request
Supplied in series, from 10 units per item. Not in stock? Then we build your series.
One or a few units only as a trial, for a company with a series in sight.
Orders are placed by email with a purchase order. We supply businesses only.
| Supply | 12 and 24 V DC, operating range 11 to 30 V DC |
|---|---|
| Input | Potentiometer, 500 Ω to 100 kΩ |
| Output | 0-5 V DC |
| Isolation | Not isolated: the output minus (terminal 4) is internally connected to the supply minus (terminal 2) |
| Setup | Three push buttons and a green LED |
| Ambient temperature | 0 to 55 °C |
| Dimensions | Board 43 x 72 mm |
| Mounting | DIN rail holder, supplied as standard |
| Terminal | Function |
|---|---|
| Terminal 1 | Supply plus, 12 or 24 V DC |
| Terminal 2 | Supply minus, also common ground for the analogue signals |
| Terminal 3 | 0-5 V output (plus) |
| Terminal 4 | 0-5 V output (minus), internally connected to terminal 2 |
| Terminal 5 | Potentiometer plus |
| Terminal 6 | Potentiometer signal (wiper) |
| Terminal 7 | Potentiometer minus |
The converters in the PR100 series are set up with three push buttons and a green LED on the module. Button 3 puts the module in programming mode, button 2 stores the value for the maximum and button 1 the value for the minimum; button 3 saves. The output can then still be fine-tuned by hand. All versions run on 12 and 24 V DC, operating range 11 to 30 V DC, at an ambient temperature of 0 to 55 °C; the board measures 43 x 72 mm and a DIN rail holder is supplied as standard. The output minus is internally connected to the supply minus: the PR100 is not galvanically isolated. To restore the factory settings, disconnect the supply, hold button 2 and reconnect the supply.
Do input and output need to be isolated, or would you rather set it up on a display? Then choose a module from the PR181 series: it is set up on a display, runs on 9 to 30 V DC and has a galvanically isolated output and an adjustable rise and fall rate. Where a PR181 exists for the same conversion, it is listed on the product page under Other version.
A different input, another range, galvanic isolation or your own logo: we adapt the module for your series.
You speak directly with the developer. Call or message Willem on +31 6 45 77 55 93.
PR100s08
Enter the quantity per delivery and per year. You will receive price and lead time by email. You then order with a purchase order.
Send the article number, the quantity per delivery and the quantity per year via WhatsApp to +31 6 83 66 55 88. Willem replies on working days.
WhatsApp Willem(opens in a new tab)