Need a different combination?
We adapt an existing module or develop a new one. Ask Willem.
Drives hydraulic valves, motors and pumps with PWM from 0-10 V, ±10 V, a joystick or a switch contact, with adjustable ramp-up and ramp-down where needed.
No module with this combination. Ask about custom electronics
| Input | Output | Isolated | Supply | Article |
|---|---|---|---|---|
| Digital or PWM | Digital or PWM | Not stated | 10 to 30 V DC | PR169 |
| Potentiometer or Digital | PWM | Yes | 18 to 30 V DC | PR159s01 |
| Digital | PWM | Yes | 18 to 30 V DC | PR159s17 |
| ±10 V | PWM | Yes | 18 to 30 V DC | PR159s25 |
| 0-10 V | PWM | Not stated | 9 to 30 V DC | PR181-X028 |
| Joystick or 0-10 V | PWM | Not stated | 9 to 30 V DC | PR181-X052 |
| Digital | PWM | No | 9 to 30 V DC | PR181-X060 |
| Digital | PWM | Not stated | 9 to 30 V DC | PR181-X061 |
| 0-10 V | PWM | Not stated | 9 to 30 V DC | PR181-X066 |
| Digital | PWM | Yes | 9 to 30 V DC | PR181-X075 |
| 0-10 V | PWM | Not stated | 12 and 24 V DC | PR505x109 |
| 0-10 V | H-bridge (motor) or PWM | Yes | 12 and 24 V DC, operating range 11 to 30 V DC | PR505x502 |
| 4-20 mA | Stepper motor | No | 12 and 24 V DC, operating range 11 to 30 V DC | PR505x503 |
| 0-10 V | Danfoss PVG | No | 12 and 24 V DC, operating range 11 to 30 V DC | PR505x505 |
| 0-5 V | PWM | No | 12 and 24 V DC, operating range 11 to 30 V DC | PR515x551 |
| 4-20 mA | Danfoss PVG | No | 24 V DC (±15 %) | W181A-P091 |
| PT100 | PWM | No | 24 V DC (±15 %) | W181A-P500 |
| Thermocouple | PWM | No | 24 V DC (±15 %) | W181A-P501 |

PR169
In: Digital or PWMOut: Digital or PWM

PR159s01
In: Potentiometer or DigitalOut: PWM

PR159s17
In: DigitalOut: PWM

PR159s25
In: ±10 VOut: PWM

PR181-X028
In: 0-10 VOut: PWM

PR181-X052
In: Joystick or 0-10 VOut: PWM

PR181-X060
In: DigitalOut: PWM

PR181-X061
In: DigitalOut: PWM

PR181-X066
In: 0-10 VOut: PWM

PR181-X075
In: DigitalOut: PWM

PR505x109
In: 0-10 VOut: PWM

PR505x502
In: 0-10 VOut: H-bridge (motor) or PWM

PR505x503
In: 4-20 mAOut: Stepper motor

PR505x505
In: 0-10 VOut: Danfoss PVG

PR515x551
In: 0-5 VOut: PWM

W181A-P091
In: 4-20 mAOut: Danfoss PVG

W181A-P500
In: PT100Out: PWM

W181A-P501
In: ThermocoupleOut: PWM
We adapt an existing module or develop a new one. Ask Willem.
The modules in the PR159 series drive two high-side switched PWM outputs; only one output is active at a time. The input side (terminals A1 to A5) is galvanically isolated from the outputs and the supply (terminals B1 to B6). Four trimmers on the module (V-max, V-start, Ramp-up and Ramp-down) set the outputs and, on most versions, the ramp rates; turning clockwise increases the value. This lets a hydraulic valve open and close smoothly, for example. The modules run on 18 to 30 V DC, deliver up to 4 A in total and are suitable for 0 to 80 °C; dimensions 45 x 82 mm.
| Article | Input | Output |
|---|---|---|
| PR159s01 | Potentiometer or Digital | PWM |
| PR159s17 | Digital | PWM |
| PR159s25 | ±10 V | PWM |
The modules in the PR181 series are set up on the display on the module, using the UP, DOWN and OK buttons. On most versions the lower and upper limits of input and output are set independently, as is the rise and fall rate of the output; the settings of each module are listed on the product page under Setup. With an adjustable rise and fall rate, motors, pumps, valves and hydraulics can be driven smoothly. On versions with an analogue output, that output is galvanically isolated from input and supply to prevent ground loops. New settings are stored through the SAVE menu. The standard DIN rail enclosure measures 45 x 83 mm (board 42.6 x 72 mm); versions with more terminals are wider. Most modules run on 9 to 30 V DC at -25 to 55 °C, non-condensing.
For some conversions there is also a version without display and without galvanic isolation in the PR100 series: it is set up with push buttons and runs on 12 and 24 V DC (operating range 11 to 30 V DC). Where one exists, it is listed on the product page under Other version.
| Article | Input | Output |
|---|---|---|
| PR181-X028 | 0-10 V | PWM |
| PR181-X052 | Joystick or 0-10 V | PWM |
| PR181-X060 | Digital | PWM |
| PR181-X061 | Digital | PWM |
| PR181-X066 | 0-10 V | PWM |
| PR181-X075 | Digital | PWM |
The PR505 modules have a built-in Wi-Fi hotspot. Hold button SW1 for about ten seconds and connect a phone, tablet or laptop to change settings or load new firmware. The modules run on 12 and 24 V DC.
| Article | Input | Output |
|---|---|---|
| PR505x109 | 0-10 V | PWM |
| PR505x502 | 0-10 V | H-bridge (motor) or PWM |
| PR505x503 | 4-20 mA | Stepper motor |
| PR505x505 | 0-10 V | Danfoss PVG |
The modules in the PR515 series have an OLED display and push buttons, so they can be set up without a computer and show the current values of inputs and outputs. They run on 12 and 24 V DC systems. Most versions can be extended on request, for example with an extra relay output, a PWM output, a bus connection (CAN bus or Modbus) or a different sensor input.
| Article | Input | Output |
|---|---|---|
| PR515x551 | 0-5 V | PWM |
The modules in the W181 series are compact and fit on a DIN rail. They have an OLED display and push buttons, so they can be set up without a computer and show the current values. A DIP switch on the board fixes basic choices. Software updates are loaded through the USB-C port and a built-in Wi-Fi hotspot. The modules run on 24 V DC. Extensions are possible on request, such as an extra relay output, a different sensor input or a bus connection.
| Article | Input | Output |
|---|---|---|
| W181A-P091 | 4-20 mA | Danfoss PVG |
| W181A-P500 | PT100 | PWM |
| W181A-P501 | Thermocouple | PWM |
Get in touch, without obligation
Contact