Not quite right?
A different input, another range, galvanic isolation or your own logo: we adapt the module.
Article number PR181-X074
The PR181-X074 converts a low-side switched PWM signal into a 0-10 V voltage, at a PWM frequency of 100 Hz to 5 kHz. The output is galvanically isolated from the input and the supply to prevent ground loops. Lower and upper limits of input and output are set independently on the display, as is the rise and fall rate of the output. As delivered, 0 % duty cycle gives 0 V and 100 % duty cycle gives 10 V.
Price on request
Lead time on request. Not in stock? We will make it.
Orders are placed by email with a purchase order. We supply businesses only.
| Supply | 9 to 30 V DC |
|---|---|
| Input | PWM, low-side switched, on terminal 3 |
| Output | 0-10 V; lower and upper limit adjustable |
| Isolation | Output galvanically isolated from input and supply |
| Setup | Display with UP, OK and DOWN buttons |
| Input frequency | 100 Hz to 5 kHz |
| Rise and fall rate | Adjustable on the display |
| Ambient temperature | -25 to 55 °C, non-condensing |
| Dimensions | 45 x 83 mm with DIN rail enclosure, 42.6 x 72 mm without |
| Factory setting | 0 % duty cycle = 0 V, 100 % duty cycle = 10 V |
| Terminal | Function |
|---|---|
| Terminal 1 | Supply plus |
| Terminal 2 | Supply minus |
| Terminal 3 | PWM input, low-side switched |
| Terminal 4 | Not used |
| Terminal 5 | Not used |
| Terminal 6 | Isolated output common |
| Terminal 7 | Isolated 0-10 V output (plus) |
| Terminal 8 | Not used |
The modules in the PR181 series are set up on the display on the module, using the UP, DOWN and OK buttons. On most versions the lower and upper limits of input and output are set independently, as is the rise and fall rate of the output; the settings of each module are listed on the product page under Setup. With an adjustable rise and fall rate, motors, pumps, valves and hydraulics can be driven smoothly. On versions with an analogue output, that output is galvanically isolated from input and supply to prevent ground loops. New settings are stored through the SAVE menu. The standard DIN rail enclosure measures 45 x 83 mm (board 42.6 x 72 mm); versions with more terminals are wider. Most modules run on 9 to 30 V DC at -25 to 55 °C, non-condensing.
For some conversions there is also a version without display and without galvanic isolation in the PR100 series: it is set up with push buttons and runs on 12 and 24 V DC (operating range 11 to 30 V DC). Where one exists, it is listed on the product page under Other version.
A different input, another range, galvanic isolation or your own logo: we adapt the module.
You speak directly with the developer. Call or message Willem on +31 6 45 77 55 93.
PR181-X074
Enter the quantity. You will receive price and lead time by email. You then order with a purchase order.
Send the article number and quantity via WhatsApp to +31 6 83 66 55 88. Willem replies on working days.
WhatsApp Willem(opens in a new tab)