PR515 module board from above: OLED display, UP, OK and DWN buttons, relay, USB-C port and terminals 1 to 22

±10 V to relay, galvanically isolated input, with OLED display

Article number PR515x602

The PR515x602 compares a -10 to +10 V signal with a set limit and switches a relay contact when it is exceeded. The input is galvanically isolated from the supply and the relay, so the signal of another system can be monitored without a ground loop. Limit and hysteresis are set on the OLED display, also for negative values, for example to detect the direction of a joystick or servo controller.

  • Supply 12 and 24 V DC, operating range 11 to 30 V DC
  • Input -10 to +10 V DC
  • Output relay contact (normally open)

Price on request

Supplied in series, from 10 units per item. Not in stock? Then we build your series.

One or a few units only as a trial, for a company with a series in sight.

Orders are placed by email with a purchase order. We supply businesses only.

Specifications

Specifications
Supply12 and 24 V DC, operating range 11 to 30 V DC
Input-10 to +10 V DC
OutputRelay contact (normally open)
IsolationInput galvanically isolated from supply and relay
SetupOLED display with UP, DOWN and OK buttons
Switching pointLimit and hysteresis adjustable; switch on above or below the limit
USBUSB-C for software updates and reading the status
Wi-FiBuilt-in hotspot for software updates
MountingDIN rail, horizontal enclosure
Internally fitted withPR181T48

Printable datasheet

Setup

  1. Connect the supply, the ±10 V source and the relay contact according to the wiring diagram supplied with the module.
  2. On the display, set the limit and the hysteresis, and choose whether the relay switches on above or below the limit.
  3. Check the current value and the relay state on the display and store with SAVE.

Application

  • Detecting the direction of a joystick or servo signal and switching a relay
  • Monitoring a ±10 V control signal from another system with isolation
  • Switching an alarm or signal lamp at too high or too low a value

PR515 series: controllers and converters with OLED display

The modules in the PR515 series have an OLED display and push buttons, so they can be set up without a computer and show the current values of inputs and outputs. They run on 12 and 24 V DC systems. Most versions can be extended on request, for example with an extra relay output, a PWM output, a bus connection (CAN bus or Modbus) or a different sensor input.

More about the PR515 series

Not quite right?

A different input, another range, galvanic isolation or your own logo: we adapt the module for your series.

Question about wiring?

You speak directly with the developer. Call or message Willem on +31 6 45 77 55 93.

PR515x602

Request price and lead time

Enter the quantity per delivery and per year. You will receive price and lead time by email. You then order with a purchase order.

The fastest way

Send the article number, the quantity per delivery and the quantity per year via WhatsApp to +31 6 83 66 55 88. Willem replies on working days.

Request

Fields marked * are required.

You can also send photos or drawings via WhatsApp(opens in a new tab).