Not quite right?
A different input, another range, galvanic isolation or your own logo: we adapt the module.
Article number PR804s07
The PR804s07 dims lighting with a single external pulse contact between terminals 4 and 5, through a low-side switched PWM output: the lamp is connected between terminal 1 (supply plus) and terminal 2. The MIN, MAX and SPEED trimmers on the board set the lower limit, upper limit and dimming speed of the output.
Price on request
Lead time on request. Not in stock? We will make it.
Other version: PR142x03. The PR142x03 from the PR142 series also dims with a single pulse contact, is likewise low-side switched and has the same terminal layout. Its PWM frequency is 122 Hz. Do you want to set the lower limit, upper limit and dimming speed yourself, or adjust the dimming curve? Then choose the PR804. Otherwise the PR142 is sufficient.
Orders are placed by email with a purchase order. We supply businesses only.
| Supply | 9 to 30 V DC, for 12 and 24 V DC systems |
|---|---|
| Input | Pulse contact (normally open) between terminals 4 and 5 |
| Output | PWM, low-side switched: lamp between terminals 1 and 2 |
| Isolation | Not galvanically isolated |
| Setup | MIN, MAX and SPEED trimmers on the board; dimming curve adjustable |
| Output current | 5 A max. |
| PWM frequency | 120 Hz |
| Ambient temperature | 0 to 80 °C |
| Dimensions | 45 x 83 mm with DIN rail enclosure, 42.5 x 72 mm without |
| Terminal | Function |
|---|---|
| Terminal 1 | Supply plus and lamp plus |
| Terminal 2 | PWM output, to the lamp minus |
| Terminal 3 | Not used |
| Terminal 4 | Pulse contact, normally open (NO) |
| Terminal 5 | Pulse contact, common |
| Terminal 6 | Supply minus (0 V) |
The dimmers in the PR804 series convert a potentiometer, a 4-20 mA or 0-10 V signal or a pulse contact into a PWM output for LED and halogen lighting. Lower limit, upper limit and output speed are set with the potentiometers on the module. The dimming curve is adjustable too, so that LED lighting responds linearly to the control. Low-side switched, the lamp is connected between terminal 1 and terminal 2; high-side switched, between terminal 2 and terminal 6. All versions run on 9 to 30 V DC, deliver up to 5 A at 120 Hz and are suitable for an ambient temperature of 0 to 80 °C. The DIN rail enclosure measures 45 x 83 mm (board 42.5 x 72 mm). If you need galvanic isolation between input, output or supply, please contact us.
A different input, another range, galvanic isolation or your own logo: we adapt the module.
You speak directly with the developer. Call or message Willem on +31 6 45 77 55 93.
PR804s07
Enter the quantity. You will receive price and lead time by email. You then order with a purchase order.
Send the article number and quantity via WhatsApp to +31 6 83 66 55 88. Willem replies on working days.
WhatsApp Willem(opens in a new tab)