Article number PR181-X062
The PR181-X062 dims lighting with two external pulse contacts: one to dim up (terminal 3, UP) and one to dim down (terminal 4, DOWN). The PWM output is low-side switched and delivers up to 3.5 A. At start-up the output goes to a default level set on the display, 50 % as delivered. The dimming speed, dimming curve and PWM frequency (3 Hz to 1 kHz) are also set on the display.
Price on request
Lead time on request. Not in stock? We will make it.
Orders are placed by email with a purchase order. We supply businesses only.
| Supply | 24 V DC ±10 % |
|---|---|
| Input | Two pulse contacts: UP on terminal 3 and DOWN on terminal 4 |
| Output | PWM, low-side switched, on terminal 6 |
| Setup | Display with UP, OK and DOWN buttons |
| Output current | 3.5 A max. |
| PWM frequency | 3 Hz to 1 kHz, adjustable |
| Ambient temperature | -25 to 55 °C, non-condensing |
| Dimensions | 45 x 83 mm with DIN rail enclosure, 42.6 x 72 mm without |
| Factory setting | Default output level 50 % |
| Terminal | Function |
|---|---|
| Terminal 1 | Supply plus (24 V DC) and lamp plus |
| Terminal 2 | Supply minus; connect externally to terminal 7 |
| Terminal 3 | UP input (dim up): push button to terminal 2 |
| Terminal 4 | DOWN input (dim down): push button to terminal 2 |
| Terminal 5 | Not used |
| Terminal 6 | PWM output, to the lamp minus |
| Terminal 7 | Supply minus; link to terminal 2 with a short wire |
| Terminal 8 | Not used |
The modules in the PR181 series are set up on the display on the module, using the UP, DOWN and OK buttons. On most versions the lower and upper limits of input and output are set independently, as is the rise and fall rate of the output; the settings of each module are listed on the product page under Setup. With an adjustable rise and fall rate, motors, pumps, valves and hydraulics can be driven smoothly. On versions with an analogue output, that output is galvanically isolated from input and supply to prevent ground loops. New settings are stored through the SAVE menu. The standard DIN rail enclosure measures 45 x 83 mm (board 42.6 x 72 mm); versions with more terminals are wider. Most modules run on 9 to 30 V DC at -25 to 55 °C, non-condensing.
For some conversions there is also a version without display and without galvanic isolation in the PR100 series: it is set up with push buttons and runs on 12 and 24 V DC (operating range 11 to 30 V DC). Where one exists, it is listed on the product page under Other version.
A different input, another range, galvanic isolation or your own logo: we adapt the module.
You speak directly with the developer. Call or message Willem on +31 6 45 77 55 93.
PR181-X062
Enter the quantity. You will receive price and lead time by email. You then order with a purchase order.
Send the article number and quantity via WhatsApp to +31 6 83 66 55 88. Willem replies on working days.
WhatsApp Willem(opens in a new tab)