PR131 module in DIN rail enclosure, front three-quarter view

16 analogue or digital inputs to Modbus RTU (RS485)

Article number PR131s01

The PR131s01 is the general version of the PR131. The 16 inputs accept analogue signals (0-10 V, 4-20 mA, 0-30 V, resistances and potentiometers) as well as on/off signals from switches and sensors. Supply and RS485 each have two terminal blocks, so several modules can be daisy-chained. The ERR LED signals a communication error and clears automatically once communication is restored.

  • Supply 10 to 31 V DC
  • Input 16 inputs: 0-10 V, 4-20 mA, 0-30 V, resistance, potentiometer or on/off signal
  • Output modbus RTU over RS485, function codes 3 (holding registers) and 4 (input registers); Modbus TCP over Ethernet optional

Price on request

Lead time on request. Not in stock? We will make it.

Orders are placed by email with a purchase order. We supply businesses only.

Specifications

Specifications
Supply10 to 31 V DC
Input16 inputs: 0-10 V, 4-20 mA, 0-30 V, resistance, potentiometer or on/off signal
OutputModbus RTU over RS485, function codes 3 (holding registers) and 4 (input registers); Modbus TCP over Ethernet optional
SetupSlave address with two rotary switches (SW1 and SW2)
ProtectionReverse polarity and overvoltage protection on inputs and supply; fuses
IndicationLEDs PWR (power), ACT (communication) and ERR (communication error)
Ambient temperature0 to 55 °C, non-condensing
MountingDIN rail; supply and RS485 can be daisy-chained

Connections

Connections
TerminalFunction
Terminal Power +Supply plus
Terminal Power EEarth
Terminal Power -Supply minus
Terminal Comm ARS485 A
Terminal Comm BRS485 B
Terminal Comm 0RS485 0 V
Terminal IN1 – IN16Inputs 1 to 16, a plus and a minus terminal per input

Datasheet (PDF)PDF, 117 kB

Setup

  1. Connect the supply, RS485 and the inputs according to the markings on the module.
  2. Set the slave address with the rotary switches SW1 and SW2.
  3. Switch on the supply: PWR lights, ACT shows communication and ERR a communication error.

Application

  • Reading analogue and digital sensors in industrial automation
  • Reading switches and sensors in the wheelhouse
  • Monitoring water quality with 4-20 mA and 0-10 V sensors
  • Monitoring the status of pumps and valves
  • Reading CO2, temperature and humidity sensors in buildings

PR131: 16 inputs to Modbus RTU

The PR131 reads 16 inputs and passes the values on via Modbus RTU over RS485 (function codes 3 and 4). The slave address is set with two rotary switches. LEDs show power (PWR), communication (ACT) and errors (ERR). The module is protected against reverse polarity and overvoltage and has fuses. Supply 10 to 31 V DC, ambient temperature 0 to 55 °C, DIN rail mounting. A version with Modbus TCP over Ethernet is optional.

The PR131s01 is the general version for analogue and digital signals: 0-10 V, 4-20 mA, 0-30 V, resistances, potentiometers and contacts. The PR131s02 is set up to read the buttons of manual call points, reporting open circuits and short circuits; it is not a certified part of a fire alarm system.

More about the PR131 series

Not quite right?

A different input, another range, galvanic isolation or your own logo: we adapt the module.

Question about wiring?

You speak directly with the developer. Call or message Willem on +31 6 45 77 55 93.

PR131s01

Request price and lead time

Enter the quantity. You will receive price and lead time by email. You then order with a purchase order.

The fastest way

Send the article number and quantity via WhatsApp to +31 6 83 66 55 88. Willem replies on working days.

Request

Fields marked * are required.

You can also send photos or drawings via WhatsApp(opens in a new tab).

Request price