PR153 in DIN rail enclosure, front three-quarter view, with the terminals for Navigation 1 and 2

Navigation lights monitor with alarm contact, up to 30 W per lamp

Article number PR153

The PR153 monitors two navigation lamps of up to 30 W each, incandescent or LED. As delivered, the alarm threshold is 2.6 W (112 mA at 24 V); it can be adjusted steplessly per lamp with a trimmer. Each lamp has its own alarm contact and indication contact, so you can see which lamp has failed.

  • Supply 24 V DC (±20 %)
  • Input two navigation lamps, measuring current 1.25 A max. per lamp
  • Output per lamp an alarm contact (NC) and an indication contact (NO); both closed while the lamp works

Price on request

Lead time on request. Not in stock? We will make it.

Other version: PR153-2. The PR153-2 is the same monitor for low-power lamps: measuring range 25 to 250 mA, alarm threshold adjustable up to 6 W and set to 3.6 W (150 mA at 24 V) as delivered. Supply, terminals, temperature range and dimensions are the same.

Orders are placed by email with a purchase order. We supply businesses only.

Specifications

Specifications
Supply24 V DC (±20 %)
InputTwo navigation lamps, measuring current 1.25 A max. per lamp
OutputPer lamp an alarm contact (NC) and an indication contact (NO); both closed while the lamp works
IsolationAlarm and indication contacts galvanically isolated from the inputs
SetupAlarm threshold per lamp with trimmers P1 and P2, stepless up to 30 W
Ambient temperature0 to 80 °C
Dimensions45 x 82 mm
Factory settingAlarm threshold 2.6 W (112 mA at 24 V)

Connections

Connections
TerminalFunction
Terminal 1Alarm contact lamp 1, normally closed (NC)
Terminal 2Alarm contact lamp 1, common (COM)
Terminal 3Indication contact lamp 1, normally open (NO)
Terminal 4Indication contact lamp 1, common (COM), internally connected to terminal 8
Terminal 5Alarm contact lamp 2, normally closed (NC)
Terminal 6Alarm contact lamp 2, common (COM)
Terminal 7Indication contact lamp 2, normally open (NO)
Terminal 8Indication contact lamp 2, common (COM), internally connected to terminal 4
Terminal 9Navigation 1: supply 0 V and lamp minus, internally connected to terminal 13
Terminal 10Not used
Terminal 11Navigation 1: lamp plus (+24 V output, the current is monitored)
Terminal 12Navigation 1: supply plus (+24 V input)
Terminal 13Navigation 2: supply 0 V and lamp minus, internally connected to terminal 9
Terminal 14Not used
Terminal 15Navigation 2: lamp plus (+24 V output, the current is monitored)
Terminal 16Navigation 2: supply plus (+24 V input)

Datasheet (PDF)PDF, 159 kB

Setup

  1. Connect the first lamp to Navigation 1: plus to terminal 11 and minus to terminal 9. Connect the supply to terminal 12 (plus) and terminal 9 (0 V).
  2. Set the alarm threshold of the first lamp with trimmer P1: turning clockwise raises the threshold, anticlockwise lowers it.
  3. Connect the second lamp to Navigation 2 (terminals 15 and 13) and the supply to terminals 16 and 13.
  4. Set the alarm threshold of the second lamp in the same way with trimmer P2.
  5. If the current drawn by a lamp falls below the set threshold, the alarm contact and the indication contact of that lamp open.

Application

  • Monitoring navigation lights on board, with incandescent or LED lamps up to 30 W

PR153: navigation lights monitoring

The PR153 modules monitor the current drawn by two navigation lamps. As long as a lamp works, the alarm contact (NC) and the indication contact (NO) are closed. If the current falls below the set threshold, both contacts open. The threshold is set per lamp with trimmers P1 and P2; turning clockwise raises it. Alarm and indication outputs are galvanically isolated from the inputs. The modules run on 24 V DC (±20 %) at 0 to 80 °C; dimensions 45 x 82 mm. If you use many identical lamps, we can preset the module for you.

The PR153 monitors lamps up to 30 W per lamp (measuring current up to 1.25 A); the threshold is set to 2.6 W (112 mA at 24 V) on delivery. The PR153-2 is for low-power lamps: measuring range 25 to 250 mA, adjustable up to 6 W, threshold on delivery 3.6 W (150 mA at 24 V).

More about the PR153 series

Not quite right?

A different input, another range, galvanic isolation or your own logo: we adapt the module.

Question about wiring?

You speak directly with the developer. Call or message Willem on +31 6 45 77 55 93.

PR153

Request price and lead time

Enter the quantity. You will receive price and lead time by email. You then order with a purchase order.

The fastest way

Send the article number and quantity via WhatsApp to +31 6 83 66 55 88. Willem replies on working days.

Request

Fields marked * are required.

You can also send photos or drawings via WhatsApp(opens in a new tab).

Request price