The PR153-2 monitors two low-power navigation lamps, incandescent or LED, with a measuring range of 25 to 250 mA per lamp. As delivered, the alarm threshold is 3.6 W (150 mA at 24 V); it can be adjusted steplessly per lamp with a trimmer, up to 6 W. Each lamp has its own alarm contact and indication contact, so you can see which lamp has failed.
Price on request
Lead time on request. Not in stock? We will make it.
Other version: PR153. The PR153 is the same monitor for lamps of up to 30 W each: measuring current up to 1.25 A, alarm threshold 2.6 W (112 mA at 24 V) as delivered. Supply, terminals, temperature range and dimensions are the same.
Orders are placed by email with a purchase order. We supply businesses only.
| Supply | 24 V DC (±20 %) |
|---|---|
| Input | Two navigation lamps, measuring range 25 to 250 mA per lamp |
| Output | Per lamp an alarm contact (NC) and an indication contact (NO); both closed while the lamp works |
| Isolation | Alarm and indication contacts galvanically isolated from the inputs |
| Setup | Alarm threshold per lamp with trimmers P1 and P2, stepless up to 6 W |
| Ambient temperature | 0 to 80 °C |
| Dimensions | 45 x 82 mm |
| Factory setting | Alarm threshold 3.6 W (150 mA at 24 V) |
| Terminal | Function |
|---|---|
| Terminal 1 | Alarm contact lamp 1, normally closed (NC) |
| Terminal 2 | Alarm contact lamp 1, common (COM) |
| Terminal 3 | Indication contact lamp 1, normally open (NO) |
| Terminal 4 | Indication contact lamp 1, common (COM), internally connected to terminal 8 |
| Terminal 5 | Alarm contact lamp 2, normally closed (NC) |
| Terminal 6 | Alarm contact lamp 2, common (COM) |
| Terminal 7 | Indication contact lamp 2, normally open (NO) |
| Terminal 8 | Indication contact lamp 2, common (COM), internally connected to terminal 4 |
| Terminal 9 | Navigation 1: supply 0 V and lamp minus, internally connected to terminal 13 |
| Terminal 10 | Not used |
| Terminal 11 | Navigation 1: lamp plus (+24 V output, the current is monitored) |
| Terminal 12 | Navigation 1: supply plus (+24 V input) |
| Terminal 13 | Navigation 2: supply 0 V and lamp minus, internally connected to terminal 9 |
| Terminal 14 | Not used |
| Terminal 15 | Navigation 2: lamp plus (+24 V output, the current is monitored) |
| Terminal 16 | Navigation 2: supply plus (+24 V input) |
The PR153 modules monitor the current drawn by two navigation lamps. As long as a lamp works, the alarm contact (NC) and the indication contact (NO) are closed. If the current falls below the set threshold, both contacts open. The threshold is set per lamp with trimmers P1 and P2; turning clockwise raises it. Alarm and indication outputs are galvanically isolated from the inputs. The modules run on 24 V DC (±20 %) at 0 to 80 °C; dimensions 45 x 82 mm. If you use many identical lamps, we can preset the module for you.
The PR153 monitors lamps up to 30 W per lamp (measuring current up to 1.25 A); the threshold is set to 2.6 W (112 mA at 24 V) on delivery. The PR153-2 is for low-power lamps: measuring range 25 to 250 mA, adjustable up to 6 W, threshold on delivery 3.6 W (150 mA at 24 V).
A different input, another range, galvanic isolation or your own logo: we adapt the module.
You speak directly with the developer. Call or message Willem on +31 6 45 77 55 93.
PR153-2
Enter the quantity. You will receive price and lead time by email. You then order with a purchase order.
Send the article number and quantity via WhatsApp to +31 6 83 66 55 88. Willem replies on working days.
WhatsApp Willem(opens in a new tab)