Article number PR505x510
The PR505x510 measures a 4-20 mA signal, for example from a pressure or level sensor, and sends the value periodically as a message on a CAN bus. This lets you add an analogue sensor to a machine or vehicle with a CAN network. The message ID, the send interval and the scaling are set through the Wi-Fi hotspot.
Price on request
Supplied in series, from 10 units per item. Not in stock? Then we build your series.
One or a few units only as a trial, for a company with a series in sight.
Orders are placed by email with a purchase order. We supply businesses only.
| Supply | 12 and 24 V DC, operating range 11 to 30 V DC |
|---|---|
| Input | 4-20 mA |
| Output | CAN bus; value as a message with adjustable ID and send interval |
| Isolation | Not galvanically isolated, the CAN bus included |
| Setup | Through the built-in Wi-Fi hotspot, with a phone, tablet or laptop; buttons SW1 to SW3 on the module |
| Communication | Message ID, send interval and scaling adjustable |
| Wi-Fi | Built-in hotspot for setup and software updates |
| Mounting | DIN rail, narrow upright enclosure |
| Internally fitted with | PR181s14 |
The PR505 modules have a built-in Wi-Fi hotspot. Hold button SW1 for about ten seconds and connect a phone, tablet or laptop to change settings or load new firmware. The modules run on 12 and 24 V DC.
A different input, another range, galvanic isolation or your own logo: we adapt the module for your series.
You speak directly with the developer. Call or message Willem on +31 6 45 77 55 93.
PR505x510
Enter the quantity per delivery and per year. You will receive price and lead time by email. You then order with a purchase order.
Send the article number, the quantity per delivery and the quantity per year via WhatsApp to +31 6 83 66 55 88. Willem replies on working days.
WhatsApp Willem(opens in a new tab)